Will fireinduced open circuit in the secondary circuit of a woundtype ct, which is operating within its. Current transformers cts are instrument transformers that are used to supply a reduced value of current to me ters, protective relays, and other instruments. Cts provide isolation from the high voltage primary, permit. This value is generally given in ohms or va voltamps. Current transformer errors and transformer inrush as. The current transformer is designed to connect in series with the line to transform the line current to the standard 5 amperes suitable for the. In this case the current transformer utilizes a moving secondary coil to. Relays are required to perform in fault current type situations. A current transformer, abbreviated ct, is a type of transformer used to measure the current of a given circuit. Two amran current transformers cts were tested to characterize the. Coupled with an ammeter, cts are used to protect the main lines of the power grid, by measuring highvoltage electrical current and preventing damage to sensitive equipment. Cts current transformers pts potential transformers. Paralleling cts for line current differential applications.
A window type current transformer is sometimes also known as a zero sequence current transformer or by the acronym, zsct. Oct 24, 2014 bar type current transformer the cable or bus bar of main circuit has been used in bar type current transformer as the primary winding. This behavior is used to calculate the value of the burden resistor for an optimum currenttovoltage relationship. Current transformers reduce high voltage currents to a much lower value and provide a convenient way of safely monitoring the actual electrical current flowing in an ac.
This transformer has a 500 a1 a current ratio and a rated output load of 1 va, which corresponds to a nominal burden of 1. The constantcurrent transformer, usually called a regulator, has a movable secondary winding that automatically changes position to provide constant current for any load within its fullload rating. Specifying current transformers for protection purposes. The polarity marks of a current transformer indicate that when a primary current enters at the polarity mark h1 of the primary, a current in. A bartype current transformer which has 1 turn on its primary and 160 turns on its secondary is to be used with a standard range of ammeters that have an internal resistance of 0. Pdf error estimation of current transformers using single. Current transformers current transformers cts provide a simple, inexpensive and yet accurate means of sensing current flow in power conductors. Mv indoor cast resin current transformers kalpa electrikal. A current transformer is defined as as an instrument transformer in which the secondary current is substantially proportional to the primary current under normal conditions of operation and differs in phase from it by an angle which is approximately zero for an appropriate direction of the connections. Abd36 wall bushing type transformer with shortcircuitable secondaries.
Bartype cts have primary connections that boltup directly to the substation bus bars. Current transformers support type support window type. Notice that the shapes of the curves are identical at each current level. Current measurement to 0 800a, seven models ct 0200 5. Apr 25, 2017 the current transformer the current transformer c.
The main role of current transformer for which it is highly known is providing the current adjusted according. The following table describes the characteristics of the ansi class transformer. The design features and construction details of current transformer shall be in accordance with the requirement stipulated in this specification and as per relevant is. American national standard for instrument transformers for. The basics of current transformers nk technologies. Indoor current tranformers, woundtype 15 kv, bil 110 kv, 5 a to 800 a, 5060 hz available jkm5 transformer, dualsecondary 1. It is high operating voltage which has been bolted to current carrying device. The current transformer will operate into either a short circuit or a resistive load until the voltage induced is enough to. The primary selection criteria is the burden placed on the secondary of the transformer. Ring core cts are available for measuring currents from 50 to 5000 amps, with windows power conductor opening size from 1 to 8 diameter. Alibaba manufacturer directory suppliers, manufacturers.
A current transformer operates with a set primary current and will try to output a constant current to the load, independent of the load. Select the model with a range that is equal to or slightly higher than the normal operating amperage. The x1 secondary terminal is the polarity terminal figure 3. Current transformer design guide an effective design of a ring type c. Country of origin thailand product type out door oilimmersed applied standard iec 600441 rated frequency hz. Addressing window type transformer proximity errors. Abstractparalleling current transformers cts is a common practice in differential or line protection applications where the number of cts exceeds the number of relay current inputs. Support type transformer for primary distribution swichgears. Another very common type of construction is the socalled window, through or donut type current transformer in which the core has an opening through which the conductor carrying the primary load current is passed.
Current transformers schneider electric documentsdownloads. The current transformer must have its secondary terminals short circuited or the burden connected before energizing the primary circuit. Notice that the shapes of the curves are identical at each current level and grow in magnitude proportional to the primary current. The balance point between coil weight and magnetic force may be adjusted to provide the desired output current.
Wall bushing type transformer with short circuitable secondaries. The classification of protection current transformers follows the following. Siemens industry catalog energy lowvoltage power distribution lowvoltage components sentron protection, switching, measuring and monitoring devices measuring devices and power monitoring measuring devices accessories 4nc current transformers for measuring purposes. Due to this, it can easily recover from dc magnetization, even with a low ac measured current.
May 16, 2017 a wound primary type current transformer b singleturn type current transformer single turn primary transformers are mostly used whereas wound primary transformers are generally used for low ratios. Bar type current transformer the cable or bus bar of main circuit has been used in bar type current transformer as the primary winding. The primary winding can consist merely of the primary current conductor passing once through an aperture in the current transformer core window or bar type, or it may consist of two or more turns wound on the core together with the secondary winding wound type. Abg24 current transformer for generator designed to work with very high primary currents. T2 is energised, a transient inrush current is drained from the emf voltage, which flows through the system. As a leading producer of medium voltage instrument transformers, sadtem manufactures this type of transformer in addition to other indoor and outdoor current transformers, voltage transformers for indoor and outdoor use, combine transformers and bushing type transformers. A bushing type current transformer usually is used in equipment where the primary conductor is a component pan of other apparatus.
Instrument transformers convert signal levels from dangerous high voltage or inconvenient high current, or current at high voltage to levels appropriate for metering. However, the concept of knee point voltage is very pertinent to protection current transformers, since they are necessarily exposed to currents of 20 or. Highcurrent transformers pfiffner instrument transformers. This type of current transformer is for use with a fully insulated conductor as the primary winding. Current transformer white paper the basics of current transformers ratio the ct ratio is the ratio of primary current input to secondary current output at full load. Schneider electric instrument transformers steven engineering. The wave shape of the output is nearly identical to the monitored circuit wave shape. This type of ct often has compensating windings which improve the accuracy across the full load range of the transformer. Current transformer basics and the current transformer. At 10x nominal rating, or 10k amperes, this ct is saturating at maximum primary conductor offset. Outdoorrated versions of this equipment are used in pole mounted primary metering installations. Current transformers are also used for street lighting circuits. As the flux in a transformer is proportional to the integral of the voltage waveform at the transformer terminals, the flux generated in the transformer t1 and t2 respectively are. Current transformer type ct20, class 1 technical data dimension.
The primary of the current transformers is directly connected in series with the line conductor that carries the entire. A current transformer ct is a type of transformer that is used to reduce or multiply an alternating current ac. Contents hide 1 different types of current transformers. This is especially true of line current differential applications applied to breakerandahalf and ringbus configurations. It produces a current in its secondary which is proportional to the current in its primary. Apr 18, 2020 suppose, you have one current transformer with current ratio 4001 a and its protection core is situated at 500 a. Current transformer precise technical data for current transformer type col24 manufacturer precise electric mfg. In this case the current transformer utilizes a moving secondary coil to vary the output so that a constant current is obtained. Ctms series current transformers produce an output of current in proportion to the monitored circuit current.
Iec 600446 requirements for protective current transformers for. Current transformers, along with voltage or potential transformers, are instrument transformers. This is the impedance of the instrument that is connected to the transformer. When the circuit burden gets too large, the ct secondary voltage becomes distorted. Chapter 16 current transformer design university of north. Addressing window type transformer proximity errors 3 to saturate and transformation begins to fail. Transformer categories insulation system liquid immersed dry type gas filled construction tank type core type shell type 1 phase 3 phase doublewound, multiwinding, auto winding configuration and type application. If the primary current of the current transformer becomes a the secondary current will still be 1. There are four typical types of current transformers. You have clicked a page that seems to be very popular. The kneepoint voltage is less applicable for metering current transformers as their accuracy is generally much tighter but constrained within a very small bandwidth of the current transformer rating, typically 1.
Simple approach integration of ideal ct secondary voltage the analysis of ct flux levels under the presence of a mix of symmetrical ac and other nonsymmetrical current wave forms, especially if any modeling of ct saturation is to be included, is a rather involved process. Street lighting requires a constant current to prevent flickering lights and a current transformer is used to provide that constant current. Device overview, moulded case current transformer, class 1 5 a secondary current. Apr 16, 2011 current transformers principle of operation of ct. Type aka current transformers are usu ally used in encased ducts, socalled iso lated phase bus ducts ibps. In this work a current transformer ct with toroidal core is analyzed from the viewpoint of the eccentricity of the primary circuit where one conductor goes through the cores window and the.
Instrument transformer basic technical information and. Suppose, you have one current transformer with current ratio 4001 a and its protection core is situated at 500 a. Measurement canada approval, t0285 or ae0320 or ae0312 when choosing your ge instrument transformer, dont forget to explore the benefits of using ges 0. What is the working principle of a current transformer. The current transformer function is different than that of a voltage transformer. Window type cts should be mounted with the h1 side of the window towards the power source.